Super 1750-1800 MoSi2 Heating Elements for High Temp Furnaces
Resistivity of MoSi2 (Molybdenum Disilicide) heating element rises dramatically when temperature rises. Power output is less than 35% of the max. output at 300°C. Resistance of a MoSi2 heating element does not change under normal use, and you can mix new and old elements together.
Generally a separator should be placed in between two shanks of heating element when installing the heating elements in the furnace. Please make sure the width of the separator matches the space of the heating element. If the separator is too big it may break the heating element during installation.
General specifications
| Name |
Value |
| Material | MoSi2 |
| Max. temperature |
1700°C (NO2, CO2, O2 and air) 1750 grade |
| Heat extensibility | 4% |
| Water absorption | 4% |
| Volume Density | 5 - 5.6 g/cm3 |
| Bend strength | 15 - 25 kg/cm3 |
| Vickers hardness | (HV) 570 kg/mm2 |
| Porosity rate | 7.4% |
Comparison
| Element | Super 1750 30x350mm | Super 1750 30x400mm | Super 1750 40x500mm | Super 1800 30x300mm | Super 1800 30x350mm | Super 1800 30x440mm |
| Compatible furnace | GCF1700 160x150x150mm | GCF1700 200x200x200mm, 300x200x200mm CF1700 200x200x200mm, 300x200x200mm |
GCF1700 400x300x300mm CF1700 400x300x300mm |
TF1700 60mm and 80mm | TF1700 60mm and 80mm | TF1700 120mm |
| Dimensions | D1: Ø7 mm D2: Ø12 mm Le: 140 mm Lu: 210 mm A: 30 mm |
D1: Ø7 mm D2: Ø12 mm Le: 190 mm Lu: 210 mm A: 30 mm |
D1: Ø7 mm D2: Ø12 mm Le: 290 mm Lu: 210 mm A: 40 mm |
D1: Ø7 mm D2: Ø12 mm Le: 120 mm Lu: 180 mm A: 30 mm |
D1: Ø7 mm D2: Ø12 mm Le: 170 mm Lu: 180 mm A: 30 mm |
D1: Ø7 mm D2: Ø12 mm Le: 250 mm Lu: 190 mm A: 30 mm |