Ai 10°C to 25°C 33L/Min 35L Capacity Recirculating Chiller
Digital temperature controlled recirculating water chiller with built-in swivel casters, recommended for our IH series induction heaters (see models below). These chillers have built-in stainless steel tank, water pump and tubing for durability and rust-free operations. Water manifold included for immediate use.
Specifications
| Model |
WAC-4 |
| Controller | Digital micro-chip controlled with LCD screen and fluid level display |
| Input power | 415VAC 50/60Hz three-phase (3PH) 3.75kW |
| Nominal cooling capacity | 10366 kcal per hour |
| Nominal cooling capacity is according to: Inlet chilled fluid temperature: 12°C Outlet chilled fluid temperature: 7°C Inlet cooling air temperature: 30°C Outlet cooling air temperature: 35°C |
|
| Compressor |
Make: Danfoss (UL Listed) Power: 415V 3-50/60Hz 8A 3750 watts, LR 25A, thermally protected Refrigerant: R407C-R134a-R404A-R507 PS: 22.6 bar, TS max: 50°C, TS min: -35°C Number of compressors installed: one |
| Water pump |
Make: LX (CMF2-50T-A-W-G-BABE) Power: 415V 50/60Hz 3-PH 550 watts 2.5/Y1.4A 3450 rpm IP55 Max liquid temperature: 70°C Pumping speed: 33L per minute Max pressure: 10 bar. H(max): 64m, H(n): 51m |
| Reservoir capacity | 35L |
| Recommended coolant | Distilled water |
| Cooling fan | Make: Weiguang (YWF4D-350S-102/34-G) Power: 415V 50/60Hz 80/150 watts 0.27A 1640 rpm Number of fans installed: two Flow rate: 142,000 cu ft per hour |
| Temperature accuracy | +/- 2 °C |
| Water inlet & outlet on chiller |
KF40 flange |
| Water manifold | Inlet: KF40 flange, outlet: 8mm quick connect with ball valve |
| Unit/shipping weight | 170 kg / 230 kg |
| Unit/shipping dimensions | 1040 x 560 x 1370 mm / 1270 x 640 x 1550 mm (DxWxH) |
| Safety | Over current, compressor delay start, water pump over load, built-in fuse, over-voltage and under- voltage, abnormal operations, phase protection and |
| Working environment | Temperature range of chilled fluid: 5°C - 35°C. Temperature difference of chilled fluid between inlet and outlet: 3°C - 8°C. It is better to use the chiller while the ambient temperature is at or below 35°C |
| Recommended to use with these induction heaters (result may vary on different applications) |
High frequency 10kW, 20kW, 30kW Mid frequency 25kW, 35kW Low frequency 25kW, 35kW |
| CE compliant | Yes |
.jpg)




Standard package
| Item |
Quantity | Image |
| WAC-4 recirculating chiller |
1 pc |
|
| Water manifold |
2 pcs |
![]() |
| KF40 flange | 2 pcs | ![]() |
| User's manual |
1 pc |
![]() |
.gif)




